mirror of
https://github.com/portapack-mayhem/mayhem-firmware.git
synced 2024-12-15 04:28:10 +00:00
02251eeeb4
* Added weather station app with 18 protocol parsers * Fix button and formatting * Set BW to 1.75m, changed to us in dsp part
111 lines
3.9 KiB
C++
111 lines
3.9 KiB
C++
|
|
#ifndef __FPROTO_THERMOPROTX4_H__
|
|
#define __FPROTO_THERMOPROTX4_H__
|
|
|
|
#include "weatherbase.hpp"
|
|
#define THERMO_PRO_TX4_TYPE_1 0b1001
|
|
#define THERMO_PRO_TX4_TYPE_2 0b0110
|
|
|
|
typedef enum {
|
|
ThermoPRO_TX4DecoderStepReset = 0,
|
|
ThermoPRO_TX4DecoderStepSaveDuration,
|
|
ThermoPRO_TX4DecoderStepCheckDuration,
|
|
} ThermoPRO_TX4DecoderStep;
|
|
|
|
class FProtoWeatherThermoProTx4 : public FProtoWeatherBase {
|
|
public:
|
|
FProtoWeatherThermoProTx4() {
|
|
sensorType = FPW_THERMOPROTX4;
|
|
}
|
|
|
|
void feed(bool level, uint32_t duration) override {
|
|
switch (parser_step) {
|
|
case ThermoPRO_TX4DecoderStepReset:
|
|
if ((!level) && (DURATION_DIFF(duration, te_short * 18) < te_delta * 10)) {
|
|
// Found sync
|
|
parser_step = ThermoPRO_TX4DecoderStepSaveDuration;
|
|
decode_data = 0;
|
|
decode_count_bit = 0;
|
|
}
|
|
break;
|
|
|
|
case ThermoPRO_TX4DecoderStepSaveDuration:
|
|
if (level) {
|
|
te_last = duration;
|
|
parser_step = ThermoPRO_TX4DecoderStepCheckDuration;
|
|
} else {
|
|
parser_step = ThermoPRO_TX4DecoderStepReset;
|
|
}
|
|
break;
|
|
|
|
case ThermoPRO_TX4DecoderStepCheckDuration:
|
|
if (!level) {
|
|
if (DURATION_DIFF(duration, te_short * 18) < te_delta * 10) {
|
|
// Found sync
|
|
parser_step = ThermoPRO_TX4DecoderStepReset;
|
|
if ((decode_count_bit == min_count_bit_for_found) &&
|
|
ws_protocol_thermopro_tx4_check()) {
|
|
data = decode_data;
|
|
data_count_bit = decode_count_bit;
|
|
ws_protocol_thermopro_tx4_remote_controller();
|
|
if (callback) callback(this);
|
|
parser_step = ThermoPRO_TX4DecoderStepCheckDuration;
|
|
}
|
|
decode_data = 0;
|
|
decode_count_bit = 0;
|
|
|
|
break;
|
|
} else if (
|
|
(DURATION_DIFF(
|
|
te_last, te_short) < te_delta) &&
|
|
(DURATION_DIFF(duration, te_long) < te_delta * 2)) {
|
|
subghz_protocol_blocks_add_bit(0);
|
|
parser_step = ThermoPRO_TX4DecoderStepSaveDuration;
|
|
} else if (
|
|
(DURATION_DIFF(
|
|
te_last, te_short) < te_delta) &&
|
|
(DURATION_DIFF(duration, te_long * 2) < te_delta * 4)) {
|
|
subghz_protocol_blocks_add_bit(1);
|
|
parser_step = ThermoPRO_TX4DecoderStepSaveDuration;
|
|
} else {
|
|
parser_step = ThermoPRO_TX4DecoderStepReset;
|
|
}
|
|
} else {
|
|
parser_step = ThermoPRO_TX4DecoderStepReset;
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
|
|
protected:
|
|
// timing values
|
|
uint32_t te_short = 500;
|
|
uint32_t te_long = 2000;
|
|
uint32_t te_delta = 150;
|
|
uint32_t min_count_bit_for_found = 37;
|
|
|
|
bool ws_protocol_thermopro_tx4_check() {
|
|
uint8_t type = decode_data >> 33;
|
|
if ((type == THERMO_PRO_TX4_TYPE_1) || (type == THERMO_PRO_TX4_TYPE_2)) {
|
|
return true;
|
|
} else {
|
|
return false;
|
|
}
|
|
}
|
|
|
|
void ws_protocol_thermopro_tx4_remote_controller() {
|
|
id = (data >> 25) & 0xFF;
|
|
battery_low = (data >> 24) & 1;
|
|
btn = (data >> 23) & 1;
|
|
channel = ((data >> 21) & 0x03) + 1;
|
|
if (!((data >> 20) & 1)) {
|
|
temp = (float)((data >> 9) & 0x07FF) / 10.0f;
|
|
} else {
|
|
temp = (float)((~(data >> 9) & 0x07FF) + 1) / -10.0f;
|
|
}
|
|
humidity = (data >> 1) & 0xFF;
|
|
}
|
|
};
|
|
|
|
#endif
|