@ -3,19 +3,17 @@
|
||||
The Key Items on the App that can be selected with the cursor and changed with the encoder knob are:
|
||||
|
||||
* **Title bar:** The usual Items may be changed and displayed.
|
||||
* **Frequency:** The default frequency of 911.6 MHz can be modified in newer firmware (the ISM band is commonly ~902 MHz to 928 MHz).
|
||||
* **Gain:** Setting are shown in order of AMP 0=0db or 1=14dB, LNA(IF) (0-40) and VGA (Baseband Gain) (0-62).
|
||||
|
||||
Fields displays in the App are as follows:
|
||||
|
||||
* **ID:** this is the meter ID (should match number/barcode printed on meter).
|
||||
* **Tp:** This is the type of meter as indicated in the message. (Likely meter type codes include Electric: 4, 5, 7, 8, 12; Gas: 0, 1, 2, 9, 12; Water: 3, 11, 13)
|
||||
* **Ty (or Tp):** This is the type of meter as indicated in the message. (Likely meter type codes include Electric: 4, 5, 7, 8, 12; Gas: 0, 1, 2, 9, 12; Water: 3, 11, 13)
|
||||
* **Consumpt:** The Meter reading value.
|
||||
* **Cnt:** The count of the number of readings with the same meter ID.
|
||||
* **Tamp:** Tamper flags. For SCM type meters the tamper flags are shown as single-digit physical/encoder tamper flags respectively. For SCM+ or IDM type meters the tamper flags are shown as a 4-digit hexadecimal value.
|
||||
* **Ct (or Cnt):** The count of the number of readings with the same meter ID (or ++ if the field width on the screen is exceeded).
|
||||
|
||||
The PortaPack ERT receiver monitors approximately 2.5 MHz centered around 911.6 MHz. It does not implement channel filters, so sensitivity is reduced in exchange for monitoring more simultaneous "channels".
|
||||
|
||||
If a FAT-formatted micro SD card is present when this mode is entered, the receiver will log received packets to a file named "ERT.TXT". The log file contains one line per packet received. Each line consists of a timestamp in sortable "YYYYMMDDHHMMSS" format, the Manchester-decoded data bits, a "/", and a per-bit Manchester coding error indicator ("1" if the data bit is in error).
|
||||
|
||||
|
||||
|
||||
|
||||
If a FAT-formatted micro SD card is present when this mode is entered, the receiver will log received packets to a file named "ERT.TXT". The log file contains one line per packet received. Each line consists of a timestamp in sortable "YYYYMMDDHHMMSS" format, the Manchester-decoded data bits, a "/", and a per-bit Manchester coding error indicator ("1" if the data bit is in error), and the meter ID. Received data that looks like it might be a packet (based on the sync bits) but has an invalid checksum will not be listed on the screen although it will be listed in the log file for debug purposes; adjusting the gain values may help in this case.
|
||||
|