@ -1,14 +1,16 @@
|
||||
[Encoder receiver transmitter](https://en.wikipedia.org/wiki/Encoder_receiver_transmitter) (ERT) is a packet radio protocol developed by Itron for automatic meter reading of water, gas and electricity. The system uses OOK short range radio which is transmitted in the unlicensed 900-920 MHz band, so that meters can be read from a passing vehicle. This is mainly used in USA. The data is not encrypted, and does not have functions to enable full control. The system is not as advanced as a smart meter and lacks the control or security in the data transfered.
|
||||
ERT
|
||||
[Encoder receiver transmitter](https://en.wikipedia.org/wiki/Encoder_receiver_transmitter) (ERT) is a packet radio protocol developed by Itron for automatic meter reading of water, gas and electricity. The system uses OOK short range radio which is transmitted in the unlicensed 902-928 MHz ISM band, so that meters can be read from a passing vehicle. This is mainly used in USA. The data is not encrypted, and does not have functions to enable full control. The system is not as advanced as a smart meter and lacks the control or security in the data transferred. Supported message protocols are IDM, SCM, and SCM+.
|
||||
|
||||
The Key Items on the App that can be selected with the cursor and changed with the encoder knob are:
|
||||
|
||||
* **Title bar:** The usual Items may be changed and displayed.
|
||||
* **Gain:** Setting are shown in order of AMP 0=0db or 1=14dB, LNA(IF) (0-40) and VGA (Baseband Gain) (0-62).
|
||||
* **ID:** this is the meter ID.
|
||||
* **Tp:** This is the type of meter. 0=Unknown,1 =IDM, 2=SCM.
|
||||
|
||||
Fields displays in the App are as follows:
|
||||
|
||||
* **ID:** this is the meter ID (should match number/barcode printed on meter).
|
||||
* **Tp:** This is the type of meter as indicated in the message. (Likely meter type codes include Electric: 4, 5, 7, 8, 12; Gas: 0, 1, 2, 9, 12; Water: 3, 11, 13)
|
||||
* **Consumpt:** The Meter reading value.
|
||||
* **Cnt:** The count of the number of readings.
|
||||
* **Cnt:** The count of the number of readings with the same meter ID.
|
||||
|
||||
The PortaPack ERT receiver monitors approximately 2.5 MHz centered around 911.6 MHz. It does not implement channel filters, so sensitivity is reduced in exchange for monitoring more simultaneous "channels".
|
||||
|
||||
|