mirror of
https://github.com/portapack-mayhem/mayhem-firmware.git
synced 2024-11-23 18:15:34 +00:00
Updated Audio Receivers (markdown)
parent
30f81cc6dc
commit
e67b85d4e2
@ -55,10 +55,10 @@ The Key Items on the App that can be seen or selected with the cursor and change
|
||||
|
||||
The next item is the setting of the bin sizes used for the waterfall (0-63) with “0” being the minimum information being the fastest display and “63” the maximum information collected the slowest display. Adjust to give a balance of speed and information seen.
|
||||
|
||||
And next right to that field , you will see Rx_IQ_CAL field.It actually can improve (8 to 10 dB's from worse CAL point to the best one ) the receiver Image Reject Ratio only in the Receiver Applications that are using Zero IF-frequency tuning ,like this SPECTRUM mode.
|
||||
This calibrated value it is stored in the SD card , /settings/rx_audio.ini .
|
||||
And next right to that field ,while you are still in SPEC mode, you will see Rx_IQ_CAL field.It actually can improve (8 to 10 dB's from worse CAL point to the best one ) the receiver Image Reject Ratio only in the Receiver Applications that are using Zero IF-frequency tuning ,like this SPECTRUM mode. This calibrated value it is stored in the SD card , /settings/rx_audio.ini .
|
||||
|
||||
To calibrate it , you will need to try to find some clean isolated continuous carrier , and try to tune it , (example , to the right of the positive frequencies ). Then you will need to start set up to 0 that CAL value (min), to make visible the bare Image mirror frequency in the other symetric left part screen. Then , you will need to adjust AMP , LNA and GAIN to receive strong enough signal to the right part (not so strong to not produce intermodulations , otherwise re-adjust again decreasing AMP, LNA, GAIN) , and not so weak , till just getting the carrier +freq. clean (desired carrier signal) , and its bare visible Image mirror Signal (in the other symetrical -xx mirror freq . (unwanted Image signal to be minimized) . Then, when you got similar situation as left below picture, you can start adjusting Rx IQ phase CAL till minimizing the received Image "mirror" signal (as in the middle below picture).
|
||||
To calibrate it , you will need to try to find some clean isolated continuous carrier , and try to tune it , (example , to the right of the positive frequencies ). Select properly the BW to try to isolate that air carrier signal (in below example , I selected BW = 2 Mhz).
|
||||
Then, to make visible the bare Image mirror frequency -that appears in the other symetric left part screen.-, you will need to start set up CAL to 0 (min). Then , you will need to adjust AMP , LNA and GAIN to receive strong enough signal to the right part (not so strong to not produce intermodulations , otherwise re-adjust again decreasing AMP, LNA, GAIN) , and not so weak , till just getting the carrier +freq. clean (desired carrier signal) , and its bare visible Image mirror Signal (in the other symetrical -xx mirror freq . (unwanted Image signal to be minimized) . Then, when you got similar situation as left below picture, you can start adjusting Rx IQ phase CAL till minimizing the received Image "mirror" signal (as in the middle below picture).
|
||||
|
||||
That below example is calibrating H2+ old r6 version (max2837) that has 31 steps ,(Note , using Hackrf r9 (max2839 ,we will have 64 steps)
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user