The windows key timeout is longer than the wgengine watchdog timeout,
which means we never reach the timeout, instead the process exits.
Reduce the timeout so if we do hit it, at least the process continues.
Signed-off-by: David Crawshaw <crawshaw@tailscale.com>
On Win10, there's a hardcoded GUID and this works.
On Win7, this GUID changes and we need to ask the tun for its
LUID and convert that from the GUID.
This commit uses the computed GUID that is placed in InterfaceName.
Diagnosed by Jason Donnenfeld. (Thanks!)
os.IsNotExist doesn't unwrap errors. errors.Is does.
The ioutil.ReadFile ones happened to be fine but I changed them so
we're consistent with the rule: if the error comes from os, you can
use os.IsNotExist, but from any other package, use errors.Is.
(errors.Is always would also work, but not worth updating all the code)
The motivation here was that we were logging about failure to migrate
legacy relay node prefs file on startup, even though the code tried
to avoid that.
See golang/go#41122
Amazingly, there doesn't seem to be a documented way of updating network
configuration programmatically in a way that Windows takes notice of.
The naturopathic remedy for this is to invoke ipconfig /registerdns, which
does a variety of harmless things and also invokes the private API that
tells windows to notice new adapter settings. This makes our DNS config
changes stick within a few seconds of us setting them.
If we're invoking a shell command anyway, why futz with the registry at
all? Because netsh has no command for changing the DNS suffix list, and
its commands for setting resolvers requires parsing its output and
keeping track of which server is in what index. Amazingly, twiddling
the registry directly is the less painful option.
Fixes#853.
Signed-off-by: David Anderson <danderson@tailscale.com>
Updating the Windows firewall is usually reasonably fast, but
sometimes blocks for 20 seconds, 4 minutes, etc. Not sure why.
Until we understand that's happening, configure it in the background
without blocking the normal control flow.
Updates #785
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>
Use golang.zx2c4.com/wireguard/windows/tunnel/winipcfg
instead of github.com/tailscale/winipcfg-go package.
Updates #760
Signed-off-by: Alex Brainman <alex.brainman@gmail.com>
Gracefully skips touching the v6 NAT table on systems that don't have
it, and doesn't configure IPv6 at all if IPv6 is globally disabled.
Signed-off-by: David Anderson <danderson@tailscale.com>
Part of unforking our winipcfg-go and using upstream (#760), move our
additions into our repo. (We might upstream them later if upstream has
interest)
Originally these were:
@apenwarr: "Add ifc.SyncAddresses() and SyncRoutes()."
609dcf2df5
@bradfitz: "winipcfg: make Interface.AddRoutes do as much as possible, return combined error"
e9f93d53f3
@bradfitz: "prevent unnecessary Interface.SyncAddresses work; normalize IPNets in deltaNets"
decb9ee8e1
Might fix it. I've spent too much time failing to reproduce the issue. This doesn't
seem to make it worse, though (it still runs for me), so I'll include this and
see if it helps others while I still work on a reliable way to reproduce it.
Updates tailscale/corp#474
Otherwise when PAC server is down, we log, and each log entry is a new
HTTP request (from logtail) and a new GetProxyForURL call, which again
logs, non-stop. This is also nicer to the WinHTTP service.
Then also hook up link change notifications to the cache to reset it
if there's a chance the network might work sooner.
This change is to restore /etc/resolv.conf after tailscale down is called. This is done by setting the dns.Manager before errors occur. Error collection is also added.
Fixes#723
* wgengine/router/router_linux.go: Switched `cidrDiff("addr")` and `cidrDiff("route")` order
Signed-off-by: Christina Wen <christina@tailscale.com>
Co-authored-by: Christina Wen <christina@tailscale.com>
Also remove rebinding logic from the windows router. Magicsock will
instead rebind based on link change signals.
Signed-off-by: David Anderson <danderson@tailscale.com>
For now. Get it working again so it's not stuck on 0.98.
Subnet relay can come later.
Updates #451
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>