To safely request and drop privileges, runtime.Lock/UnlockOSThread and
windows.Impersonate/RevertToSelf should be called. Add these calls to
winutil.EnableCurrentThreadPrivilege so that callers don't need to worry
about it.
Updates https://github.com/tailscale/corp/issues/15488
Signed-off-by: Andrew Lytvynov <awly@tailscale.com>
(*Token).IsAdministrator is supposed to return true even when the user is
running with a UAC limited token. The idea is that, for the purposes of
this check, we don't care whether the user is *currently* running with
full Admin rights, we just want to know whether the user can
*potentially* do so.
We accomplish this by querying for the token's "linked token," which
should be the fully-elevated variant, and checking its group memberships.
We also switch ipn/ipnserver/(*Server).connIsLocalAdmin to use the elevation
check to preserve those semantics for tailscale serve; I want the
IsAdministrator check to be used for less sensitive things like toggling
auto-update on and off.
Fixes#10036
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
I didn't clean up the more idiomatic map[T]bool with true values, at
least yet. I just converted the relatively awkward struct{}-valued
maps.
Updates #cleanup
Change-Id: I758abebd2bb1f64bc7a9d0f25c32298f4679c14f
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>
In order for the installer to restart the GUI correctly post-upgrade, we
need the GUI to be able to register its restart preferences.
This PR adds API support for doing so. I'm adding it to OSS so that it
is available should we need to do any such registrations on OSS binaries
in the future.
Updates https://github.com/tailscale/corp/issues/13998
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
* We update wingoes to pick up new version information functionality
(See pe/version.go in the https://github.com/dblohm7/wingoes repo);
* We move the existing LogSupportInfo code (including necessary syscall
stubs) out of util/winutil into a new package, util/osdiag, and implement
the public LogSupportInfo function may be implemented for other platforms
as needed;
* We add a new reason argument to LogSupportInfo and wire that into
localapi's bugreport implementation;
* We add module information to the Windows implementation of LogSupportInfo
when reason indicates a bugreport. We enumerate all loaded modules in our
process, and for each one we gather debug, authenticode signature, and
version information.
Fixes#7802
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
Previously, tailscale upgrade was doing the bare minimum for checking
authenticode signatures via `WinVerifyTrustEx`. This is fine, but we can do
better:
* WinVerifyTrustEx verifies that the binary's signature is valid, but it doesn't
determine *whose* signature is valid; tailscale upgrade should also ensure that
the binary is actually signed *by us*.
* I added the ability to check the signatures of MSI files.
* In future PRs I will be adding diagnostic logging that lists details about
every module (ie, DLL) loaded into our process. As part of that metadata, I
want to be able to extract information about who signed the binaries.
This code is modelled on some C++ I wrote for Firefox back in the day. See
https://searchfox.org/mozilla-central/rev/27e4816536c891d85d63695025f2549fd7976392/toolkit/xre/dllservices/mozglue/Authenticode.cpp
for reference.
Fixes#8284
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
In order to improve our ability to understand the state of policies and
registry settings when troubleshooting, we enumerate all values in all subkeys.
x/sys/windows does not already offer this, so we need to call RegEnumValue
directly.
For now we're just logging this during startup, however in a future PR I plan to
also trigger this code during a bugreport. I also want to log more than just
registry.
Fixes#8141
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
This adds an initial and intentionally minimal configuration for
golang-ci, fixes the issues reported, and adds a GitHub Action to check
new pull requests against this linter configuration.
Signed-off-by: Andrew Dunham <andrew@du.nham.ca>
Change-Id: I8f38fbc315836a19a094d0d3e986758b9313f163
I realized that a lot of the problems that we're seeing around migration and
LocalBackend state can be avoided if we drive Windows pref migration entirely
from within tailscaled. By doing it this way, tailscaled can automatically
perform the migration as soon as the connection with the client frontend is
established.
Since tailscaled is already running as LocalSystem, it already has access to
the user's local AppData directory. The profile manager already knows which
user is connected, so we simply need to resolve the user's prefs file and read
it from there.
Of course, to properly migrate this information we need to also check system
policies. I moved a bunch of policy resolution code out of the GUI and into
a new package in util/winutil/policy.
Updates #7626
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
This updates all source files to use a new standard header for copyright
and license declaration. Notably, copyright no longer includes a date,
and we now use the standard SPDX-License-Identifier header.
This commit was done almost entirely mechanically with perl, and then
some minimal manual fixes.
Updates #6865
Signed-off-by: Will Norris <will@tailscale.com>
Goal: one way for users to update Tailscale, downgrade, switch tracks,
regardless of platform (Windows, most Linux distros, macOS, Synology).
This is a start.
Updates #755, etc
Change-Id: I23466da1ba41b45f0029ca79a17f5796c2eedd92
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>
I added util/winutil/LookupPseudoUser, which essentially consists of the bits
that I am in the process of adding to Go's standard library.
We check the provided SID for "S-1-5-x" where 17 <= x <= 20 (which are the
known pseudo-users) and then manually populate a os/user.User struct with
the correct information.
Fixes https://github.com/tailscale/tailscale/issues/869
Fixes https://github.com/tailscale/tailscale/issues/2894
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
The //go:build syntax was introduced in Go 1.17:
https://go.dev/doc/go1.17#build-lines
gofmt has kept the +build and go:build lines in sync since
then, but enough time has passed. Time to remove them.
Done with:
perl -i -npe 's,^// \+build.*\n,,' $(git grep -l -F '+build')
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>
It's normal for HKLM\SOFTWARE\Policies\Tailscale to not exist but that
currently produces a lot of log spam.
Signed-off-by: Adrian Dewhurst <adrian@tailscale.com>
I added new functions to winutil to obtain the state of a service and all
its depedencies, serialize them to JSON, and write them to a Logf.
When tstun.New returns a wrapped ERROR_DEVICE_NOT_AVAILABLE, we know that wintun
installation failed. We then log the service graph rooted at "NetSetupSvc".
We are interested in that specific service because network devices will not
install if that service is not running.
Updates https://github.com/tailscale/tailscale/issues/5531
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
AFAICT this isn't documented on MSDN, but based on the issue referenced below,
NRPT rules are not working when a rule specifies > 50 domains.
This patch modifies our NRPT rule generator to split the list of domains
into chunks as necessary, and write a separate rule for each chunk.
For compatibility reasons, we continue to use the hard-coded rule ID, but
as additional rules are required, we generate new GUIDs. Those GUIDs are
stored under the Tailscale registry path so that we know which rules are ours.
I made some changes to winutils to add additional helper functions in support
of both the code and its test: I added additional registry accessors, and also
moved some token accessors from paths to util/winutil.
Fixes https://github.com/tailscale/coral/issues/63
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
I wrote this code way back at the beginning of my tenure at Tailscale when we
had concerns about needing to restore deleted machine keys from backups.
We never ended up using this functionality, and the code is now getting in the
way, so we might as well remove it.
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
It makes the most sense to have all our utility functions reside in one place.
There was nothing in corp that could not reasonably live in OSS.
I also updated `StartProcessAsChild` to no longer depend on `futureexec`,
thus reducing the amount of code that needed migration. I tested this change
with `tswin` and it is working correctly.
I have a follow-up PR to remove the corresponding code from corp.
The migrated code was mostly written by @alexbrainman.
Sourced from corp revision 03e90cfcc4dd7b8bc9b25eb13a26ec3a24ae0ef9
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
This patch adds new functions to be used when accessing system policies,
and revises callers to use the new functions. They first attempt the new
registry path for policies, and if that fails, attempt to fall back to the
legacy path.
We keep non-policy variants of these functions because we should be able to
retain the ability to read settings from locations that are not exposed to
sysadmins for group policy edits.
The remaining changes will be done in corp.
Updates https://github.com/tailscale/tailscale/issues/3584
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
It was broken on Windows:
Error: util\winutil\winutil_windows.go:15:7: regBase redeclared in this block
Error: D:\a\tailscale\tailscale\util\winutil\winutil_notwindows.go:7:17: previous declaration
Error: util\winutil\winutil_windows.go:29:6: getRegString redeclared in this block
Error: D:\a\tailscale\tailscale\util\winutil\winutil_notwindows.go:9:40: previous declaration
Error: util\winutil\winutil_windows.go:47:6: getRegInteger redeclared in this block
Error: D:\a\tailscale\tailscale\util\winutil\winutil_notwindows.go:11:48: previous declaration
Error: util\winutil\winutil_windows.go:77:6: isSIDValidPrincipal redeclared in this block
Error: D:\a\tailscale\tailscale\util\winutil\winutil_notwindows.go:13:38: previous declaration
Change-Id: Ib1ce4b647f5711547840c736b933a6c42bf09583
Signed-off-by: Brad Fitzpatrick <bradfitz@tailscale.com>
Our current workaround made the user check too lax, thus allowing deleted
users. This patch adds a helper function to winutil that checks that the
uid's SID represents a valid Windows security principal.
Now if `lookupUserFromID` determines that the SID is invalid, we simply
propagate the error.
Updates https://github.com/tailscale/tailscale/issues/869
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
utils/winutil/vss contains just enough COM wrapping to query the Volume Shadow Copy service for snapshots.
WalkSnapshotsForLegacyStateDir is the friendlier interface that adds awareness of our actual use case,
mapping the snapshots and locating our legacy state directory.
Updates #3011
Signed-off-by: Aaron Klotz <aaron@tailscale.com>
This helper allows us to retrieve `DWORD` and `QWORD` values from the Tailscale key in the Windows registry.
Signed-off-by: Aaron Klotz <aaron@tailscale.com>